Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.306
Filtrar
1.
Cancer Imaging ; 24(1): 46, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556864

RESUMO

BACKGROUND: PSMA PET/CT is the most sensitive molecular imaging modality for prostate cancer (PCa), yet much of the developing world has little or no access to PET/CT. [99mTc]Tc-PSMA scintigraphy (PS) is a cheaper and more accessible gamma camera-based alternative. However, many resource-constrained departments have only a single camera without tomographic or hybrid imaging functionality, and camera time is frequently in high demand. Simplifying imaging protocols by limiting the field of view (FOV) and omitting SPECT/CT or even SPECT may provide a partial solution. The aim was thus to determine the adequacy of PS planar-only and/or SPECT-only imaging protocols with a limited FOV. METHODS: The scans of 95 patients with histologically proven PCa who underwent PS with full-body planar and multi-FOV SPECT/CT were reviewed. The detection rates for uptake in the prostate gland/bed and in metastases were compared on planar, SPECT, and SPECT/CT. The agreement between modalities was calculated for the detection of metastases and for staging. The impact of imaging a limited FOV was determined. RESULTS: Pathological prostatic uptake was seen in all cases on SPECT/CT (excluding two post-prostatectomy patients), 90.3% of cases on SPECT, and 15.1% on planar images (p < 0.001). Eleven (11.7%) patients had seminal vesicle involvement on SPECT/CT, which was undetectable/indistinguishable on planar images and SPECT. The agreement between modalities was moderate to good (κ = 0.41 to 0.61) for the detection of nodal metastases, with detection rates that did not differ significantly (SPECT/CT = 11.6%, SPECT = 8.4%, planar = 5.3%). Detection rates for bone metastases were 14.7% (SPECT/CT) and 11.6% (SPECT and planar). Agreement between modalities for the detection of bone metastases was good (κ = 0.73 to 0.77). Three (3.1%) patients had visceral metastases on SPECT/CT, two of which were detected on SPECT and planar. There was good agreement between modalities for the TNM staging of patients (κ = 0.70 to 0.88). No metastatic lesions were missed on the limited FOV images. CONCLUSION: When PS scintigraphy is performed, SPECT/CT is recommended. However, the lack of SPECT/CT capabilities should not preclude the use of PS in the presence of limited resources, as both planar and SPECT imaging are adequate and will correctly stage most PCa patients. Furthermore, time-based optimisations are achievable by limiting the FOV to exclude the distal lower limbs.


Assuntos
Neoplasias Ósseas , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos , Região de Recursos Limitados , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias Ósseas/secundário
2.
EJNMMI Phys ; 11(1): 32, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38564043

RESUMO

BACKGROUND: Peptide receptor radionuclide therapy with 177Lu-DOTATATE is a recognized option for treating neuroendocrine tumors and has few toxicities, except for the kidneys and bone marrow. The bone marrow dose is generally derived from a SPECT/CT image-based method with four timepoints or from a blood-based method with up to 9 timepoints, but there is still no reference method. This retrospective single-center study on the same cohort of patients compared the calculated bone marrow dose administered with both methods using mono, bi- or tri-exponential models. For the image-based method, the dose was estimated using Planetdose© software. Pearson correlation coefficients were calculated. We also studied the impact of late timepoints for both methods. RESULTS: The bone marrow dose was calculated for 131 treatments with the blood-based method and for 17 with the image-based method. In the former, the median absorbed dose was 15.3, 20.5 and 28.3 mGy/GBq with the mono-, bi- and tri-exponential model, respectively. With the image-based method, the median absorbed dose was 63.9, 41.9 and 60.8 with the mono-, bi- and tri-exponential model, respectively. Blood samples after 24h post-injection did not evidence any change in the absorbed bone marrow dose with the bi-exponential model. On the contrary, the 6-day post-injection timepoint was more informative with the image-based model. CONCLUSION: This study confirms that the estimated bone marrow dose is significantly lower with the blood-based method than with the image-based method. The blood-based method with a bi-exponential model proved particularly useful, without the need for blood samples after 24h post-injection. Nevertheless, this blood-based method is based on an assumption that needs to be more validated. The important difference between the two methods does not allow to determine the optimal one to estimate the true absorbed dose and further studies are necessary to compare with biological effects.

3.
J Nucl Med ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575187

RESUMO

Personalized dose-based treatment planning requires accurate and reproducible noninvasive measurements to ensure safety and effectiveness. Dose estimation using SPECT is possible but challenging for alpha (α)-particle-emitting radiopharmaceutical therapy (α-RPT) because of complex γ-emission spectra, extremely low counts, and various image-degrading artifacts across a plethora of scanner-collimator configurations. Through the incorporation of physics-based considerations and skipping of the potentially lossy voxel-based reconstruction step, a recently developed projection-domain low-count quantitative SPECT (LC-QSPECT) method has the potential to provide reproducible, accurate, and precise activity concentration and dose measures across multiple scanners, as is typically the case in multicenter settings. To assess this potential, we conducted an in silico imaging trial to evaluate the LC-QSPECT method for a 223Ra-based α-RPT, with the trial recapitulating patient and imaging system variabilities. Methods: A virtual imaging trial titled In Silico Imaging Trial for Quantitation Accuracy (ISIT-QA) was designed with the objectives of evaluating the performance of the LC-QSPECT method across multiple scanner-collimator configurations and comparing performance with a conventional reconstruction-based quantification method. In this trial, we simulated 280 realistic virtual patients with bone-metastatic castration-resistant prostate cancer treated with 223Ra-based α-RPT. The trial was conducted with 9 simulated SPECT scanner-collimator configurations. The primary objective of this trial was to evaluate the reproducibility of dose estimates across multiple scanner-collimator configurations using LC-QSPECT by calculating the intraclass correlation coefficient. Additionally, we compared the reproducibility and evaluated the accuracy of both considered quantification methods across multiple scanner-collimator configurations. Finally, the repeatability of the methods was evaluated in a test-retest study. Results: In this trial, data from 268 223RaCl2 treated virtual prostate cancer patients, with a total of 2,903 lesions, were used to evaluate LC-QSPECT. LC-QSPECT provided dose estimates with good reproducibility across the 9 scanner-collimator configurations (intraclass correlation coefficient > 0.75) and high accuracy (ensemble average values of recovery coefficients ranged from 1.00 to 1.02). Compared with conventional reconstruction-based quantification, LC-QSPECT yielded significantly improved reproducibility across scanner-collimator configurations, accuracy, and test-retest repeatability ([Formula: see text] Conclusion: LC-QSPECT provides reproducible, accurate, and repeatable dose estimations in 223Ra-based α-RPT as evaluated in ISIT-QA. These findings provide a strong impetus for multicenter clinical evaluations of LC-QSPECT in dose quantification for α-RPTs.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38576115

RESUMO

BACKGROUND: Phenotypes of CANVAS are increasingly diversified, including bradykinesia and dysautonomia, so that its primary differential diagnoses are multiple system atrophy-cerebellar type (MSA-c), and spinocerebellar ataxia type 3 (SCA3). This case series aims to highlight key molecular imaging findings in CANVAS. CASES: We report a case series of six patients with CANVAS who underwent nuclear medicine examinations in our center and 13 patients from the literature. These include 18F-FDG brain positron emission tomography (PET), single photon emission computed tomography (SPECT) of dopamine transporter (DaT) activity, and 123I-MIBG cardiac scintigraphy of noradrenergic transmission. CONCLUSIONS: In CANVAS, 18F-FDG brain PET mainly shows cerebellar hypometabolism, with preserved brainstem and striatum metabolism, contrasting with SCA3 and MSA-c. Dopaminergic denervation on scintigraphy seems to be associated with clinical parkinsonism, ranging from normal to severely impaired DaT SPECT. Additionally, 123I-MIBG cardiac scintigraphy might show denervation in CANVAS, similar to SCA3, but not in most MSA-c patients.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38591997

RESUMO

AIM: We aimed to test the hypothesis if combining coronary artery calcium score (Ca-score) as a quantitative anatomical marker of coronary atherosclerosis with high-sensitive cardiac troponin as a quantitative biochemical marker of myocardial injury provided incremental value in the detection of functional relevant CAD (fCAD) and risk stratification. METHODS AND RESULTS: Consecutive patients undergoing myocardial perfusion SPECT (MPS) without prior CAD were enrolled. The diagnosis of fCAD was based on the presence of ischemia on MPS and coronary angiography- fCAD was centrally adjudicated in the diagnostic and prognostic domain. Diagnostic accuracy was evaluated using the area under receiver-operating characteristic curve. The composite of cardiovascular death and non-fatal acute myocardial infarction (AMI) within 730 days were the primary prognostic endpoints.Among 1715 patients eligible for the diagnostic analysis, 399 patients had fCAD. The combination of Ca-Score and hs-cTnT had good diagnostic accuracy for the diagnosis of fCAD, AUC 0.79 (95 % CI 0.77-0.81), but no incremental value compared to the Ca-score alone (AUC 0.79 (95%CI 0.77-0.81, p=0.965). Similar results were observed using hs-cTnI (AUC 0.80, 95%CI 0.77-0.82) instead of hs-cTnT.Among 1709 patients (99.7%) with available follow-up, 59 patients (3.5%) suffered the composite primary prognostic endpoint (nonfatal AMI n=34, CV death n=28).Both, Ca-score and hs-cTnT had independent prognostic value. Increased risk was restricted to patients with elevation in both markers. CONCLUSION: The combination of the Ca-score with hs-cTnT increases the prognostic accuracy for future events defining fCAD, but does not provide incremental value versus the Ca-Score alone for the diagnosis of fCAD.

6.
EJNMMI Phys ; 11(1): 35, 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581559

RESUMO

BACKGROUND: The administration of a 166Ho scout dose is available as an alternative to 99mTc particles for pre-treatment imaging in Selective Internal Radiation Therapy (SIRT). It has been reported that the 166Ho scout dose may be more accurate for the prediction of microsphere distribution and the associated therapy planning. The aim of the current study is to compare the scintigraphic imaging characteristics of both isotopes, considering the objectives of the pre-treatment imaging using clinically geared phantoms. METHODS: Planar and SPECT/CT images were obtained using a NEMA image quality phantom in different phantom setups and another body-shaped phantom with several inserts. The influence of collimator type, count statistics, dead time effects, isotope properties and patient obesity on spatial resolution, contrast recovery and the detectability of small activity accumulations was investigated. Furthermore, the effects of the imaging characteristics on personalized dosimetry are discussed. RESULTS: The images with 99mTc showed up to 3 mm better spatial resolution, up to two times higher contrast recovery and significantly lower image noise than those with 166Ho. The contrast-to-noise ratio was up to five times higher for 99mTc than for 166Ho. Only when using 99mTc all activity-filled spheres could be distinguished from the activity-filled background. The measurements mimicking an obese patient resulted in a degraded image quality for both isotopes. CONCLUSIONS: Our measurements demonstrate better scintigraphic imaging properties for 99mTc compared to 166Ho in terms of spatial resolution, contrast recovery, image noise, and lesion detectability. While the 166Ho scout dose promises better prediction of the microsphere distribution, it is important to consider the inferior imaging characteristics of 166Ho, which may affect individualized treatment planning in SIRT.

7.
Hemodial Int ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38571365

RESUMO

This article report a 40-year-old male patient who underwent total thyroidectomy and forearm auto-transplantation in another hospital for secondary hyperparathyroidism. After 4 years of follow-up, the level of parathyroid hormone continued to increase, and ultrasound showed nodules in the neck and right forearm, which were considered to be of parathyroid origin. Technetium 99m sestamibi single photon emission computed tomography and computed tomography (Tc-99m-MIBI SPECT/CT) imaging showed increased radioactive uptake in the submuscular soft tissue nodule of the right medial forearm, maximum standardized uptake value (SUVmax) is 0.98, which was identified as transplanted functioning parathyroid tissue. No parathyroid imaging activity was found in the neck. The patient then underwent partial removal of ectopic parathyroid tissue from the right forearm. Pathological examination confirmed parathyroid tissue, and removal was followed by a rapid decline in serum parathyroid hormone levels.

8.
Front Cardiovasc Med ; 11: 1364772, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38576422

RESUMO

Background: The value of semiquantitative resting myocardial perfusion imaging (MPI) in coronary artery disease (CAD) is limited. At present, quantitative MPI can be performed by a new cadmium zinc tellurium single-photon emission computed tomography (CZT-SPECT) scan. The quantitative index of resting myocardial blood flow (MBF) has received little attention, and its manifestations and clinical value in the presence of unstable coronary blood flow have not been clarified. Purpose: In patients with ST-segment elevation myocardial infarction (STEMI), whether resting MBF can provide additional value of blood flow than semi-quantitative resting MPI is not sure. We also explored the influencing factors of resting MBF. Methods: This was a retrospective clinical study. We included 75 patients with STEMI in the subacute phase who underwent resting MPI and dynamic scans after reperfusion therapy. General patient information, STEMI-related data, MPI, gated MPI (G-MPI), and resting MBF data were collected and recorded. According to the clinically provided culprit vessels, the resting MBF was divided into ischemic MBF and non-ischemic MBF. The paired Wilcoxon signed-rank test was used for resting MBF. The receiver operating characteristic (ROC) curves were used to determine the optimal threshold for ischemia, and multiple linear regression analysis was used to analyze the influencing factors of resting MBF. Results: There was a statistically significant difference between the ischemic MBF and non-ischemic MBF [0.59 (0.47-0.72) vs. 0.76 (0.64-0.93), p < 0.0001]. The ROC curve analysis revealed that resting MBF could identify ischemia to a certain extent, with a cutoff value of 0.5975, area under the curve (AUC) = 0.666, sensitivity = 55.8%, and specificity = 68.7%. Male sex and summed rest score (SRS) were influencing factors for resting MBF. Conclusion: To a certain extent, resting MBF can suggest residual ischemia after reperfusion therapy in patients with STEMI. There was a negative correlation between male sex, SRS, and ischemic MBF. A lower resting MBF may be associated with more severe myocardial ischemia.

9.
J Clin Med ; 13(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38610749

RESUMO

Radioiodine imaging in initial perioperative settings, after the total thyroidectomy, includes pre-treatment and post-treatment radioiodine imaging. While the benefit of post-treatment whole-body imaging (PT-WBI) is well established, the role of diagnostic whole-body imaging (dx WBI), prior to radioiodine (I-131) ablative or therapeutic doses, is controversial. Dx WBI has been abandoned in most nuclear medicine centers long ago. Planar low-dose dxWBI provides the volume of postoperative thyroid remnants, but it cannot detect occult metastatic foci in the neck. The modern integrated multimodality, i.e., SPECT/CT imaging, provides three dimensional images and accurate anatomic/metabolic data. This hybrid technology offers better spatial resolution but not better sensitivity. Dx WBI has low theranostic power because of the radioiodine indifference and low detection sensitivity for small-volume nodal disease in the neck. Since dx WBI cannot clarify the paratracheal cervical uptake, thyroid remnants may be easily misinterpreted as nodal disease, leading to a false N upstaging (from N0 stage to N1 stage) in DTC patients. Post-ablation I-131 imaging has a significant role in the initial staging of radioiodine-avid DTC and in the identification of non-radioiodine avid tumors. Additionally, SPECT/CT in the post-treatment setting provides more accurate initial TNM staging and better risk stratification of DTC patients. Post-treatment I-131 imaging is obligatory and must be performed in all DTC patients who receive radioiodine treatment.

10.
Parasitol Int ; 101: 102895, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38614255

RESUMO

Various opportunistic infections develop during immunodeficiency due to human immunodeficiency virus (HIV) infection. The treatment options for malignant lymphoma (ML) and toxoplasmic encephalitis (TE) are completely different; therefore, their discrimination is critical. A 25-year-old female of foreign nationality had been experiencing headaches for several weeks and suddenly developed convulsions. Brain computed tomography revealed multiple intracranial lesions; therefore, the patient was referred to the neurosurgery department. Brain magnetic resonance imaging (MRI) revealed multiple masses with surrounding edema, accompanied by enhanced contrast. The largest mass (2 cm) in the left occipital lobe exhibited ringed contrast enhancement. Her blood test results showed a CD4 count of 40/µL, positive HIV Ag/Ab, HIV-RNA level of 56 × 104 copies/mL, positive anti-Toxoplasma IgG (63 IU/mL), and negative anti-Toxoplasma IgM. 201Tl- single photon emission computed tomography (201Tl-SPECT) revealed abnormal accumulation only in the tumor in the left occipital lobe (early T/N ratio, 3.034; delayed T/N ratio, 2.738; retention index, 0.9), which was suspected to be a ML. Both tumors, with or without high accumulation of 201Tl, were subjected to craniotomy biopsy. Pathological examination revealed infiltration of small lymphocytes with a necrotic background. The patient was diagnosed with TE based on a positive result of a tissue polymerase chain reaction test for Toxoplasma gondii. Two weeks after sulfamethoxazole and trimethoprim combination therapy, MRI imaging showed dramatic improvement in multiple brain tumors. This case is atypical because ML was ruled out despite high 201Tl-SPECT uptake and retention. Careful diagnosis through pathological examination and DNA testing is important.

11.
EJNMMI Radiopharm Chem ; 9(1): 30, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625607

RESUMO

BACKGROUND: Radionuclide molecular imaging can be used to visualize the expression levels of molecular targets. Affibody molecules, small and high affinity non-immunoglobulin scaffold-based proteins, have demonstrated promising properties as targeting vectors for radionuclide tumour imaging of different molecular targets. B7-H3 (CD276), an immune checkpoint protein belonging to the B7 family, is overexpressed in different types of human malignancies. Visualization of overexpression of B7-H3 in malignancies enables stratification of patients for personalized therapies. Affinity maturation of anti-B7-H3 Affibody molecules as an approach to improve the binding affinity and targeting properties was recently investigated. In this study, we tested the hypothesis that a dimeric format may be an alternative option to increase the apparent affinity of Affibody molecules to B7-H3 and accordingly improve imaging contrast. RESULTS: Two dimeric variants of anti-B7-H3 Affibody molecules were produced (designated ZAC12*-ZAC12*-GGGC and ZAC12*-ZTaq_3-GGGC). Both variants were labelled with Tc-99m (99mTc) and demonstrated specific binding to B7-H3-expressing cells in vitro. [99mTc]Tc-ZAC12*-ZAC12*-GGGC showed subnanomolar affinity (KD1=0.28 ± 0.10 nM, weight = 68%), which was 7.6-fold higher than for [99mTc]Tc-ZAC12*-ZTaq_3-GGGC (KD=2.1 ± 0.9 nM). Head-to-head biodistribution of both dimeric variants of Affibody molecules compared with monomeric affinity matured SYNT-179 (all labelled with 99mTc) in mice bearing B7-H3-expressing SKOV-3 xenografts demonstrates that both dimers have lower tumour uptake and lower tumour-to-organ ratios compared to the SYNT-179 Affibody molecule. CONCLUSION: The improved functional affinity by dimerization does not compensate the disadvantage of increased molecular size for imaging purposes.

12.
Nucl Med Biol ; 132-133: 108910, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38636351

RESUMO

INTRODUCTION: Radiolabeled antibodies are promising tools for cancer diagnosis using nuclear medicine. A DOTA-chelating system is useful for preparing immuno-positron emission tomography and immuno-single-photon emission computed tomography probes with various radiometals. Radiolabeled antibodies are generally metabolized in the reticuloendothelial system, producing radiometabolites after proteolysis in hepatic lysosomes. Because of the bulkiness and extremely high hydrophilicity of DOTA, radiometabolites containing a radiometal-DOTA complex typically exhibit high and persistent localization in hepatic lysosomes. Radioactivity in the liver impairs the accurate diagnosis of cancer surrounding the liver and liver metastasis, and a high tumor/liver ratio is desirable. In this study, we reduced the hepatic radioactivity of radiometal-labeled antibodies containing a DOTA-chelating system. A cleavable linkage was inserted to liberate the radiometabolite, which exhibited a short residence time in hepatocytes. METHODS: Using indium-111 (111In)-labeled antibodies, we prepared 111In-labeled galactosyl-neoglycoalbumins (NGAs) because they are useful for evaluating the residence time of radiometabolites in the liver. An 111In-labeled NGA with a cleavable linkage ([111In]In-DO3AiBu-Bn-FGK-NGA) was administered to normal mice, and biodistribution studies and metabolic analyses of urinary and fecal samples were performed with comparison to an 111In-labeled NGA prepared by a conventional method ([111In]In-DOTA-Bn-SCN-NGA). Then, 111In-labeled antibodies ([111In]In-DO3AiBu-Bn-FGK-IgG and [111In]In-DOTA-Bn-SCN-IgG) were prepared using a procedure similar to that for 111In-labeled NGAs. In vitro plasma stability and biodistribution were investigated for both 111In-labeled antibodies in U87MG tumor-bearing mice. RESULTS: Through the liberation of radiometabolites including [111In]In-DO3AiBu-Bn-F, [111In]In-DO3AiBu-Bn-FGK-NGA was cleared more rapidly from the liver than [111In]In-DOTA-Bn-SCN-NGA (4.07 ± 1.54%ID VS 71.68 ± 3.03%ID at 6 h postinjection). [111In]In-DO3AiBu-Bn-FGK-IgG exhibited lower tumor accumulation (8.83 ± 1.48%ID/g) but a significantly higher tumor/liver ratio (2.21 ± 0.53) than [111In]In-DOTA-Bn-SCN-IgG (11.65 ± 2.17%ID/g in the tumor and a tumor/liver ratio of 0.85 ± 0.18) at 72 h after injection. CONCLUSION: A molecular design that reduces the high and persistent hepatic radioactivity of radiolabeled antibodies by liberating radiometabolites with a short hepatic residence time in lysosomes would be applicable for radiometal-labeled antibodies using a DOTA-chelating system.

13.
Biomed J ; : 100721, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38636899

RESUMO

Extracellular vesicles derived from human umbilical cord-derived mesenchymal stem cells (UCMSC-EVs) have been postulated to have therapeutic potential for various diseases. However, the biodistribution and pharmacokinetics of these vesicles are still unclear. For a better understanding of the in vivo properties of UCMSC-EVs, in the present study, these vesicles were first radiolabeled with Technetium-99 m (99mTc-UCMSC-EVs) and evaluated using in vivo single photon emission computed tomography (SPECT) imaging and biodistribution experiments. SPECT images demonstrated that the liver and spleen tissues mainly took up the 99mTc-UCMSC-EVs. The biodistribution study observed slight uptake in the thyroid and stomach, indicating that 99mTc-UCMSC-EVs was stable at 24 h in vivo. The pharmacokinetic analyses of the blood half-life demonstrated the quick distribution phase (0.85 ±â€¯0.28 min) and elimination phase (25.22 ±â€¯20.76 min) in mice. This study provides a convenient and efficient method for 99mTc-UCMSC-EVs preparation without disturbing their properties. In conclusion, the biodistribution, quick elimination, and suitable stability in vivo of 99mTc-UCMSC-EVs were quantified by the noninvasive imaging and pharmacokinetic analyses, which provides useful information for indication selection, dosage protocol design, and toxicity assessment in future applications.

14.
J Nucl Med ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637141

RESUMO

With the development of new radiopharmaceutical therapies, quantitative SPECT/CT has progressively emerged as a crucial tool for dosimetry. One major obstacle of SPECT is its poor resolution, which results in blurring of the activity distribution. Especially for small objects, this so-called partial-volume effect limits the accuracy of activity quantification. Numerous methods for partial-volume correction (PVC) have been proposed, but most methods have the disadvantage of assuming a spatially invariant resolution of the imaging system, which does not hold for SPECT. Furthermore, most methods require a segmentation based on anatomic information. Methods: We introduce DL-PVC, a methodology for PVC of 177Lu SPECT/CT imaging using deep learning (DL). Training was based on a dataset of 10,000 random activity distributions placed in extended cardiac-torso body phantoms. Realistic SPECT acquisitions were created using the SIMIND Monte Carlo simulation program. SPECT reconstructions without and with resolution modeling were performed using the CASToR and STIR reconstruction software, respectively. The pairs of ground-truth activity distributions and simulated SPECT images were used for training various U-Nets. Quantitative analysis of the performance of these U-Nets was based on metrics such as the structural similarity index measure or normalized root-mean-square error, but also on volume activity accuracy, a new metric that describes the fraction of voxels in which the determined activity concentration deviates from the true activity concentration by less than a certain margin. On the basis of this analysis, the optimal parameters for normalization, input size, and network architecture were identified. Results: Our simulation-based analysis revealed that DL-PVC (0.95/7.8%/35.8% for structural similarity index measure/normalized root-mean-square error/volume activity accuracy) outperforms SPECT without PVC (0.89/10.4%/12.1%) and after iterative Yang PVC (0.94/8.6%/15.1%). Additionally, we validated DL-PVC on 177Lu SPECT/CT measurements of 3-dimensionally printed phantoms of different geometries. Although DL-PVC showed activity recovery similar to that of the iterative Yang method, no segmentation was required. In addition, DL-PVC was able to correct other image artifacts such as Gibbs ringing, making it clearly superior at the voxel level. Conclusion: In this work, we demonstrate the added value of DL-PVC for quantitative 177Lu SPECT/CT. Our analysis validates the functionality of DL-PVC and paves the way for future deployment on clinical image data.

15.
J Clin Med ; 13(5)2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38592092

RESUMO

(1) Background: The objective of this study was to determine the optimal post-processing model for dynamic cadmium-zinc-telluride single-photon emission computed tomography (CZT-SPECT). (2) Methods: A total of 235 patients who underwent diagnostic invasive coronary angiography within three months of the SPECT and those who had coronary computed tomography angiography (CCTA) before SPECT (within 3 months) were enrolled in this study. Each SPECT study was processed to obtain global and regional stress myocardial blood flow (sMBF), rest-MBF (rMBF), myocardial flow reserve (MFR) and flow difference (FD) estimates obtained with 1-tissue-compartment (1TCM) and net retention (NR) modes, both with and without attenuation correction. (3) Results: The use of AC led to significantly higher sMBF, rMBF and DF values obtained by 1TCM compared those values derived by 1TCM with NAC; the lowest values of stress MBF and rest MBF were obtained by 1TCM_NAC. The resting flow, MFR and DF were significantly (p < 0.005) higher in the AC model than in NAC. All quantitative variables were significantly (p < 0.05) higher in NR_NAC than in the 1TC_NAC model. Finally, sMBF, rMBF and FD showed significantly (p < 0.05) higher values by using 1TMC_AC compared to NR_AC. (4) Conclusions: We suggested that 1-compartment and net retention models correctly reflect coronary microcirculation and can be used for clinical practice for evaluating quantitative myocardial perfusion by dynamic SPECT. Attenuation correction is an important step in post-processing dynamic SPECT data, which increases the consistency and diagnostic accuracy of models.

16.
Mol Pharm ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38606663

RESUMO

Chemokines and chemokine receptors are indispensable to play a key role in the development of malignant tumors. As one of the most widely expressed chemokine receptors, chemokine (C-X-C motif) receptor 4 (CXCR4) has been a popular research focus. In most tumors, CXCR4 expression is significantly upregulated. Moreover, integrated nuclide diagnosis and therapy targeting CXCR4 show great potential. [68Ga]Ga-pentixafor, a radioligand targeting CXCR4, exhibits a strong affinity for CXCR4 both in vivo and in vitro. However, [177Lu]Lu-pentixather, the therapeutic companion of [68Ga]Ga-pentixafor, requires significant refinement to mitigate its pronounced hepatic biodistribution. The objective of this study was to synthesize theranostic molecular tracers with superior CXCR4 targeting functions. The Daudi cell line, which highly expressed CXCR4, and the MM.1S cell line, which weakly expressed CXCR4, were used in this study. Based on the pharmacophore cyclo (-d-Tyr-n-me-d-Orn-l-Arg-L-2-NAL-Gly-) (CPCR4) of pentixafor, six tracers were synthesized: [124I]I-1 ([124I]I-CPCR4), [99mTc]Tc-2 ([99mTc]Tc-HYNIC-CPCR4), [124I]I-3 ([124I]I-pentixafor), [18F]AlF-4 ([18F]AlF-NETA-CPCR4), [99mTc]Tc-5 ([99mTc]Tc-MAG3-CPCR4) and [124I]I-6 ([124I]I-pentixafor-Ga) and their radiochemical purities were all higher than 95%. After positron emission tomography (PET)/single-photon emission computed tomography (SPECT) imaging, the [124I]I-6 group exhibited the best target-nontarget ratio. At the same time, comparing the [68Ga]Ga-pentixafor group with the [124I]I-6 group, we found that the [124I]I-6 group had a better target-nontarget ratio and lower uptake in nontarget organs. Therefore, compound 6 was selected for therapeutic radionuclide (131I) labeling, and the tumor-bearing animal models were treated with [131I]I-6. The volume of the tumor site was significantly reduced in the treatment group compared with the control group, and no significant side effects were found. [124I]I-6 and [131I]I-6 showed excellent affinity for targeting CXCR4, and they showed great potential for the integrated diagnosis and treatment of tumors with high CXCR4 expression.

17.
J Biol Inorg Chem ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38607392

RESUMO

Aß42 plaque formation is one of the preliminary pathologic events that occur post traumatic brain injury (TBI) which is also among the most noteworthy hallmarks of AD. Their pre symptomatic detection is therefore vital for better disease management. Chalcone-picolinic acid chelator derivative, 6-({[(6-carboxypyridin-2-yl)methyl](2-{4-[(2E)-3-[4-(dimethyl amino)phenyl]prop-2-enoyl]phenoxy}ethyl)amino}methyl)pyridine-2-carboxylic acid, Py-chal was synthesized to selectively identify amyloid plaques formed post head trauma using SPECT imaging by stable complexation to 99mTc with > 97% efficiency without compromising amyloid specificity. The binding potential of the Py-chal ligand to amyloid plaques remained high as confirmed by in vitro binding assay and photophysical spectra. Further, the Py-chal complex stained amyloid aggregates in the brain sections of rmTBI mice model. In vivo scintigraphy in TBI mice model displayed high uptake followed by high retention while the healthy rabbits displayed higher brain uptake followed by a rapid washout attributed to absence of amyloid plaques. Higher uptake in brain of TBI model was also confirmed by ex vivo biodistribution analysis wherein brain uptake of 3.38 ± 0.2% ID/g at 2 min p.i. was observed for TBI mice model. This was followed by prolonged retention and more than twofold higher activity as compared to sham mice brain. This preliminary data suggests the specificity of the radiotracer for amyloid detection post head trauma and applicability of 99mTc labeled Py-chal complex for TBI-induced ß-amyloid SPECT imaging.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38635050

RESUMO

PURPOSE: Lutetium-177 [177Lu]Lu-PSMA-617 radioligand therapy (RLT) represents a significant advancement for metastatic castration-resistant prostate cancer (mCRPC), demonstrating improvements in radiographic progression free survival (rPFS) and overall survival (OS) with a low rate of associated side effects. Currently, most post-therapy SPECT/CT is conducted at 24 h after infusion. This study examines the clinical utility of a next-generation multi-detector Cadmium-Zinc-Telluride (CZT) SPECT/CT system (StarGuide) in same-day post-infusion assessment and early treatment response to [177Lu]Lu-PSMA-617. METHODS: In this retrospective study, 68 men with progressive mCRPC treated with [177Lu]Lu-PSMA-617 at our center from June 2022 to June 2023 were evaluated. Digital whole-body SPECT/CT imaging was performed after [177Lu]Lu-PSMA-617infusion (mean ± SD: 1.8 ± 0.6 h, range 1.1-4.9 h). Quantitative analysis of [177Lu]Lu-PSMA-617 positive lesions was performed in patients who underwent at least 2 post-therapy SPECT/CT, using liver parenchyma uptake as reference. Metrics including [177Lu]Lu-PSMA-617 positive total tumor volume (Lu-TTV), SUVmax and SUVmean were calculated. These quantitative metrics on post-infusion SPECT/CT images after cycles 1, 2 and 3 were correlated with overall survival (OS), prostate specific antigen-progression free survival (PSA-PFS) as defined by prostate cancer working group 3 (PCWG3), and PSA decrease over 50% (PSA50) response rates. RESULTS: 56 patients (means age 76.2 ± 8.1 years, range: 60-93) who underwent at least 2 post-therapy SPECT/CT were included in the image analysis. The whole-body SPECT/CT scans (~ 12 min per scan) were well tolerated, with 221 same-day scans performed (89%). At a median of 10-months follow-up, 33 (58.9%) patients achieved PSA50 after [177Lu]Lu-PSMA-617 treatment and median PSA-PFS was 5.0 months (range: 1.0-15 months) while median OS was not reached. Quantitative analysis of SPECT/CT images showed that 37 patients (66%) had > 30% reduction in Lu-TTV, associated with significantly improved overall survival (median not reached vs. 6 months, P = 0.008) and PSA-PFS (median 6 months vs. 1 months, P < 0.001). However, changes in SUVmax or SUVmean did not correlate with PSA-PFS or OS. CONCLUSION: We successfully implemented same-day post-therapy SPECT/CT after [177Lu]Lu-PSMA-617 infusions. Quantitation of 1-2 h post-therapy SPECT/CT images is a promising method for assessing treatment response. However, the approach is currently limited by its suboptimal detection of small tumor lesions and the necessity of incorporating a third-cycle SPECT/CT to mitigate the effects of any potential treatment-related flare-up. Further investigation in a larger patient cohort and prospective validation is essential to confirm these findings and to explore the role of SPECT/CT as a potential adjunct to PSMA PET/CT in managing mCRPC.

19.
J Nucl Med Technol ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627013

RESUMO

In cardiac nuclear medicine examinations, absorption in the body is the main factor in the degradation of the image quality. The Chang and external source methods were used to correct for absorption in the body. However, fundamental studies on attenuation correction for electrocardiogram (ECG)-synchronized CT imaging have not been performed. Therefore, we developed and improved an ECG-synchronized cardiac dynamic phantom and investigated the synchronized time-phase-gated attenuation correction (STPGAC) method using ECG-synchronized SPECT and CT images of the same time phase. Methods: As a basic study, SPECT was performed using synchronized time-phase-gated (STPG) SPECT and non-phase-gated (NPG) SPECT. The attenuation-corrected images were, first, CT images with the same time phase as the ECG waveform of the gated SPECT acquisition (with CT images with the ECG waveform of the CT acquisition as the reference); second, CT images with asynchronous ECG; third, CT images of the 75% region; and fourth, CT images of the 40% region. Results: In the analysis of cardiac function in the phantom experiment, left ventricle ejection fraction (heart rate, 11.5%-13.4%; myocardial wall, 49.8%-55.7%) in the CT images was compared with that in the STPGAC method (heart rate, 11.5%-13.3%; myocardial wall, 49.6%-55.5%), which was closer in value to that of the STPGAC method. In the phantom polar map segment analyses, none of the images showed variability (F (10,10) < 0.5, P = 0.05). All images were correlated (r = 0.824-1.00). Conclusion: In this study, we investigated the STPGAC method using a SPECT/CT system. The STPGAC method showed similar values of cardiac function analysis to the CT images, suggesting that the STPGAC method accurately reconstructed the distribution of blood flow in the myocardial region. However, the target area for attenuation correction of the heart region was smaller than that of the whole body, and changing the gated SPECT conditions and attenuation-corrected images did not affect myocardial blood flow analysis.

20.
EJNMMI Res ; 14(1): 40, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630381

RESUMO

BACKGROUND: The aim of this study was to assess the impact of the post-injection electrical seizure duration on the identification of the seizure onset zone (SOZ) in ictal brain perfusion SPECT in presurgical evaluation of drug-resistant epilepsy. METHODS: 176 ictal SPECT performed with 99mTc-HMPAO (n = 140) or -ECD (n = 36) were included retrospectively. Visual interpretation of the SPECT images (together with individual MRI and statistical hyperperfusion maps) with respect to lateralization (right, left, none) and localization (temporal, frontal, parietal, occipital) of the SOZ was performed by 3 independent readers. Between-readers agreement was characterized by Fleiss' κ. An ictal SPECT was considered "lateralizing" if all readers agreed on right or left hemisphere. It was considered "localizing" if it was lateralizing and all readers agreed on the same lobe within the same hemisphere. The impact of injection latency and post-injection seizure duration on the proportion of lateralizing/localizing SPECT was tested by ANOVA with dichotomized (by the median) injection latency and post-injection seizure duration as between-subjects factors. RESULTS: Median [interquartile range] (full range) of injection latency and post-injection seizure duration were 30 [24, 40] (3-120) s and 50 [27, 70] (-20-660) s, respectively. Fleiss' κ for lateralization of the SOZ was largest for the combination of early (< 30 s) injection and long (> 50 s) post-injection seizure duration (κ = 0.894, all other combinations κ = 0.659-0.734). Regarding Fleiss' κ for localization of the SOZ in the 141 (80.1%) lateralizing SPECT, it was largest for early injection and short post-injection seizure duration (κ = 0.575, all other combinations κ = 0.329-0.368). The proportion of lateralizing SPECT was lower with short compared to long post-injection seizure duration (estimated marginal means 74.3% versus 86.3%, p = 0.047). The effect was mainly driven by cases with very short post-injection seizure duration ≤ 10 s (53.8% lateralizing). Injection latency in the considered range had no significant impact on the proportion of lateralizing SPECT (p = 0.390). The proportion of localizing SPECT among the lateralizing cases did not depend on injection latency or post-injection seizure duration (p ≥ 0.603). CONCLUSIONS: Short post-injection seizure duration is associated with a lower proportion of lateralizing cases in ictal brain perfusion SPECT.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...